Reasons for excessive oil consumption of the compressor unit or oil in the discharged compressed air
1. Excessive refueling. Oil level is too high, the airflow will be oil separator oil into the compressed air. Caused by the discharge of compressed air in the oil content exceeds the standard. So the amount of oil should be controlled in the red line on the yellow line.
2. The failure of the minimum pressure spring leads to low starting pressure, the pressure difference between the front and rear of the oil separator is too large, the oil and gas mixture in the tank has a high flow rate, and the oil condensed on the cylinder wall and oil separator filter element will be taken away by the high-speed airflow, thus affecting the effect of oil and gas separation.
3. The oil separator filter element is blocked or damaged, check and clean and replace if necessary.
4. Oil separator return pipe is blocked, check and clean.
5. Leakage in the air cooler system, check and repair and make up the leakage.
6. Oil use time overdue, oil quality deterioration. Clean the compressor unit and replace the oil with qualified labeling.